Proposed by Martin Perlot, SilverLeaf Electronics.
AC source DGNs are defined for Inverter, Generator, and Transfer Switch, but no device is defined for the case of AC power from a "generic" source such as the shore cord. This set of DGNs implements the AC Point DGNs for such a source. We also define a "Generic AC Source" device, and assign Instance 1 to the Shore Cord. These DGNs would also be useful any time that AC power is measured in the coach outside of the transfer switch, such as in a "smart" AC breaker panel.
New DSA: 139 - Generic AC Source
New DGNs:
1FEBBh - GENERIC_AC_STATUS_1
1FEBAh - GENERIC_AC_STATUS_2
1FEB9h - GENERIC_AC_STATUS_3
1FEB8h - GENERIC_AC_STATUS_4
1FEB7h - GENERIC_ACFAULT_CONFIGURATION_STATUS_1
1FEB6h - GENERIC_ACFAULT_CONFIGURATION_STATUS_2
1FEB5h - GENERIC_ACFAULT_CONFIGURATION_COMMAND_1
1FEB4h - GENERIC_ACFAULT_CONFIGURATION_COMMAND_2