Addition: Generic AC Source

Proposed by Martin Perlot, SilverLeaf Electronics.

AC source DGNs are defined for Inverter, Generator, and Transfer Switch, but no device is defined for the case of AC power from a "generic" source such as the shore cord. This set of DGNs implements the AC Point DGNs for such a source. We also define a "Generic AC Source" device, and assign Instance 1 to the Shore Cord. These DGNs would also be useful any time that AC power is measured in the coach outside of the transfer switch, such as in a "smart" AC breaker panel.

New DSA: 139 - Generic AC Source
New DGNs:

1FEBBh - GENERIC_AC_STATUS_1
1FEBAh - GENERIC_AC_STATUS_2
1FEB9h - GENERIC_AC_STATUS_3
1FEB8h - GENERIC_AC_STATUS_4
1FEB7h - GENERIC_ACFAULT_CONFIGURATION_STATUS_1
1FEB6h - GENERIC_ACFAULT_CONFIGURATION_STATUS_2
1FEB5h - GENERIC_ACFAULT_CONFIGURATION_COMMAND_1
1FEB4h - GENERIC_ACFAULT_CONFIGURATION_COMMAND_2

AttachmentSize
Generic AC Source DGNs.doc31.5 KB