While editing the Layer document the Administrator team discovered a couple of discrepancies.
The section in the updated layer document for this will be 6.52.2b Signal and parameter definition.
The following discrepancies need to be resolved.
Byte Bit Name Data Type Unit Value description
0 6-7 Cavity Uint2 - 1=Fridge, 2=Freezer (Fridge should be 0 or 1)
2 to 3 - Current Temperature Uint16 °C see Table 5.3
3 to 4 - Set Temperature Uint16 °C see Table 5.3
There is an overlap of byte 2-3 and 3-4 working group will need to resolve. The DGN will not be assigned until discrepancies are resolved.
Eric Schuh of Dometic
Eric Schuh of Dometic proposed following
Byte Bit Data Type Unit Value Description
0 0-5 Instance uint6 - 1-60
6-7 Cavity uint2 - 0=fridge, 1=freezer
1 0-1 Light uint2 - 00b – all off
01b – all on
2-3 Door Switch uint2 - 00b – closed
01b – open
2-3 Current Temperature uint16 °C see Table 5.3
4-5 Set Temperature uint16 °C see Table 5.3
6 0-3 Fuel Source uint4 - 000b – Gas
001b – DC Voltage
010b – AC voltage
4-7 Refrigerator Mode uint4 - 0000b – off
0001b – on
0010b- night
7 Compressor Speed uint8 % see Table 5.3